RSD RS-320胸/肺模體,RSD RS-320肺部模體,RSD RS-320胸部模體詳細(xì)介紹:
RSD RS-320胸/肺模體,RSD RS-320肺部模體,RSD RS-320胸部模體
Alderson肺/胸部模體是一個(gè)專門的模體,提供高度的現(xiàn)實(shí)主義在胸部X光片。肺/胸部模體模型帶有可拆卸的隔膜肺對(duì)插入物,無(wú)冠狀動(dòng)脈。
RSD RS-320胸/肺模體,RSD RS-320肺部模體,RSD RS-320胸部模體特點(diǎn)和優(yōu)點(diǎn)
廣泛的血管細(xì)節(jié)
不同程度的血管對(duì)比可用
可互換的正常和病理性肺
從頸部延伸到隔膜下方
選擇動(dòng)物肺以匹配成年男性的大小。
允許肺交換,并提供無(wú)限數(shù)量的配置和疾病模擬。
肺動(dòng)脈注射血液當(dāng)量塑料。
提供血液當(dāng)量肺動(dòng)脈,或添加低或高對(duì)比劑。
RSD RS-320胸/肺模體,RSD RS-320肺部模體,RSD RS-320胸部模體為了證明不同的病理狀況,納入了五種標(biāo)準(zhǔn)病狀(可選項(xiàng)目):
第一個(gè)左肋尖端有兩個(gè)連續(xù)的0.5厘米結(jié)節(jié)
0.6厘米結(jié)節(jié)疊加在左下葉大血管
1.5厘米結(jié)節(jié),左側(cè)縱隔陰影
0.6厘米結(jié)節(jié)與右肺動(dòng)脈混合
肺右下葉
保修信息:1年保修
LUNG/CHEST PHANTOMS
Extensive Vascular Detail
Different Degrees of Vascular Contrast Available
Interchangeable Normal and Pathological Lungs
Developed in conjunction with the University at California, Irvine's Department of Radiological Sciences, the Alderson Lung/Chest Phantom is a specialized phantom, providing a high degree of realism in chest radiography.
The Alderson Lung/Chest Phantom extends from the neck to below the diaphragm. It is molded about a male skeleton, corresponding to the external body size of a patient, 5 feet, 9 inches (175 cm) tall and weighing
162 lbs (73.5 kg). RSD materials are equivalent to natural bone and soft tissues.
Animal lungs are selected to match the size of an adult male. Lungs are fixed in the inflated state and are molded to conform to the pleural cavities of the phantom. The pulmonary arteries are injected with a blood equivalent plastic.
The Lung/Chest Phantom with simulated left coronary artery reveals several areas of coronary artery irregularity and narrowing.
To demonstrate different pathological conditions, five standard pathologies are incorporated: Please call for pricing.
Two contiguous 0.5 cm nodules at the tip of the first left rib.
A 0.6 cm nodule superimposed with large vessel in the left lower lobe.
A 1.5 cm nodule, left mediastinal shadow.
A 0.6 cm nodule blending in with the right pulmonary artery.
Pneumonia in the right lower lobe.
The Lung/Chest Phantom is available either with the diaphragm permanently sealed to the interior of the phantom, fixing the lungs in place, or with a removable diaphragm, which permits the interchange of lungs, and provides an unlimited number of configurations and disease simulations.
Custom pathologies are available as wrap around sheets on either or both lungs.
All models are available with blood-equivalent pulmonary arteries, or with low or high contrast media added.
MODEL NUMBERS
RS-310:Lung/Chest Phantom with permanently sealed diaphragm
RS-315:Lung/Chest Phantom with permanently sealed diaphragm and left coronary artery
RS-320:Lung/Chest Phantom with removeable diaphragm lung pair insert without coronary artery
RS-330:Lung/Chest Phantom with removeable diaphragm lung pair insert with coronary artery
RS-340:Lung/Pair insert without coronary artery
RS-345:Lung/Pair insert with coronary artery